| Typus | Indices technici | |||||
| Exitus | Tensio continua | 5V | Duodecim voltia | 24V | 36V | 48V |
| Current aestimatus | 7A | 3A | 1.5A | 1A | 0.8A | |
| Potentia aestimata | 35W | 36W | 36W | 36W | 38.4W | |
| Unda et strepitus | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
| Ambitus regulationis tensionis | ±10% | |||||
| Praecisio tensionis | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| Ratio adaptationis linearis | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Ratio regulationis oneris | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Tempus surgendi stellae | 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC (pleno onere) | |||||
| Tempus serva | 30ms/230VAC 12ms/115VA (pleno onere) | |||||
| Inputum | Frequentia/amplitudo tensionis | 85-264VAC/120-373VDC 47Hz-63Hz | ||||
| Efficacia (typica) | 82% | 86% | 88% | 88% | 89% | |
| Currens operans | 0.7A/115VAC 0.42A/230VAC | |||||
| Currens impetus | Initium frigidum: 45A/230VAC | |||||
| Fugae fluxus | <0.75mA 240VAC | |||||
| Proprietates tutelae | Praesidium contra onus nimium | Typus tutelae: modus ructus, remove condicionem abnormalem et automatice ad normalem redire | ||||
| Protectio contra supertensionem | Genus tutelae: claudere exitum et automatice ad statum normalem denuo incipere | |||||
| Scientia environmentalis | Temperatura et humiditas operandi | -30℃~+70℃; 20%~90RH | ||||
| Temperatura et humiditas repositionis | -40℃~+85℃; 10%~95RH | |||||
| Securitas | Resistentia pressionis | Ingressus – egressus: 4KVAC ingressus – casus: 2KVAC egressus – casus: 1.25kvac duratio: 1 minutum | ||||
| Impedans insulationis | Ingressus – egressus et ingressus – testa, egressus – testa: 500 VDC / 100mΩ 25℃, 70% RH | |||||
| Alia | Magnitudo | 98*82*30mm | ||||
| Pondus netum / pondus grossum | 230g/246g | |||||
| Observationes | (1) Mensura undulationis et strepitus: Linea parium contortorum 12" cum condensatore 0.1µF et 47µF parallelis in terminali adhibita, mensura ad latitudinem transmissionis 20MHz perficitur. (2) Efficacia probatur sub tensione ingressus 230 VCA, onere nominali et temperatura ambienti 25 ℃. Accuratio: errorem configurationis, rationem adaptationis linearis et rationem adaptationis oneris comprehendens. Methodus probationis rationis adaptationis linearis: probatio a tensione humili ad tensionem altam sub onere nominali. Methodus probationis rationis adaptationis oneris: ab onere nominali 0%-100%. Tempus initii metitur in statu initii frigidi, et machina commutationis frequentis celeris tempus initii augere potest. Cum altitudo supra 2000 metra est, temperatura operandi 5/1000 deminui debet. | |||||