| Typus | Indices technici | |||||
| Exitus | Tensio continua | 5V | Duodecim voltia | 24V | 36V | 48V |
| Current aestimatus | 18A | 8.3A | 4.1A | 2.8A | 2.1A | |
| Potentia aestimata | 90W | 100.8W | 100.8W | 100.8W | 100.8W | |
| Unda et strepitus | <75mVp-p | <120mVp-p | <150mVp-p | <240mVp-p | <240mVp-p | |
| Ambitus regulationis tensionis | ±10% | |||||
| Praecisio tensionis | ±2.0% | ±1.0% | ||||
| Ratio adaptationis linearis | ±0.5% | |||||
| Ratio regulationis oneris | <±1.5% | <±0.5% | <±0.5% | <±0.5% | <±0.5% | |
| Inputum | Frequentia/amplitudo tensionis | 180-264VCA 47Hz-63Hz (254VCC~370VCC) | ||||
| Efficacia (typica) | >75% | >82% | >84% | >84% | >84% | |
| Currens operans / Currens impetus | <1.2A 220VAC; 220VAC 36A | |||||
| Tempus incipiendi | 200ms, 50ms, 20ms; 220V AC | |||||
| Proprietates tutelae | Protectio contra onus nimium | ≥105%-150%; Egressus cursus constans +VO ad punctum pressionis demissae cadit, egressus interclusus ad reset: iterum potentia accendenda. | ||||
| Praesidium contra breves circuitus | +VO ad punctum pressionis demissae cadit ut emissionem claudat | |||||
| Scientia environmentalis | Temperatura et humiditas operandi | -10°C~+50°C; 20%~90°RH | ||||
| Temperatura et humiditas repositionis | -20°C~+85°C; 10%~95°RH | |||||
| Securitas | Resistentia pressionis | Ingressus – egressus: 1.5KVAC ingressus-casus: 1.5KVAC egressus-casus: 0.5kvac duratio: 1 minutum | ||||
| fluxus electricus | Ingressus-egressus 1.5KVAC <5mA | |||||
| fluxus electricus | Ingressus-egressus 220VAC <1mA | |||||
| Impedans insulationis | Ingressus-exitus et ingressus-cortex, ingressus-cortex: 500 VDC/100mΩ | |||||
| Alia | Magnitudo | 199*98*38mm (L*A*A) | ||||
| Pondus netum / pondus grossum | 535g/580.8g | |||||
| Observationes | (1) Mensura undulationis et strepitus: Linea parium contortorum 12" cum condensatore 0.1µF et 47µF parallelis in terminali adhibita, mensura ad latitudinem transmissionis 20MHz perficitur. | |||||
| (2) Efficacia probatur sub tensione ingressus 230 VCA, onere nominali et temperatura ambiente 25°C. Accuratio: errorem configurationis, rationem adaptationis linearis et rationem adaptationis oneris comprehendens. Methodus probationis rationis adaptationis linearis: probatio a tensione humili ad tensionem altam sub onere nominali. Methodus probationis rationis adaptationis oneris: ab onere nominali 0%-100%. Tempus initii metitur in statu initii frigidi, et machina commutationis frequentis celeris tempus initii augere potest. Cum altitudo supra 2000 metra est, temperatura operandi 5/1000 deminui debet. | ||||||
Duae topologiae ad hoc propositum considerandae sunt: linearis regulatio et commutativa. Linearis regulatio aptissima est ad usus qui strepitum humilem requirunt, dum commutativa aptior est ad machinas portatiles ubi diuturnitas pilae et efficacia magni momenti sunt.