Classificatio
- Secundum montaturam: fixa et extractibilis
- Secundum polos: tres polos, quattuor polos
- Secundum modos operationis: motoria et manualia (conservatio et reparatio)
- Secundum emissionem: moderator intelligens supercurrentis, emissio instantanea (vel mora) subtensionis, et emissio derivativa.
- Facultas moderatoris currentis excessivi intelligentis:
- classificatio: genus H (normale), genus M (normale intelligens), genus L (oeconomicum)
- Munus habet protectionis temporis extremi inversi longae morae onerationis excessivae
- Functio protectiva unius phasis terrestris
- Functio indicationis: indicatio currentis constituendi, indicatio currentis actionis, indicatio tensionis singulorum fili (mentionem facere debet ut iubes).
- Functio alarmis
- Functio autodiagnostica
- Functio probationis
Conditio Ambitus pro Operatione et Installatione
- Temperatura ambientis: -5℃ ~ 40℃, et temperatura media intra 24 horas infra +35℃ (exceptis mandatis specialibus).
- Altitudo loci installationis: ≤2000m.
- Humiditas relativa: Non excedens 50% ad maximam temperaturam ambientis +40°C. Temperatura inferiore, humiditas maior permittitur, sed minima temperatura media in mense non excedens +25°C durante mense humidissimo, et maxima humiditas relativa media menstrua non excedens 90% in illo mense, et consideratis roribus in superficie mercium, quae ob mutationem temperaturae apparerent.
- Praesidium contra pollutionem: gradus 3.
- Categoriae institutionis: I pro circuitibus principalibus interruptorium, bobinis liberationis tensionis minimae et circuitu primario transformatorum; III pro aliis circuitibus auxiliaribus et circuitu moderationis.
- Interruptores in navibus et in regione tropica humida adhibiti sine influxu aeris humidi, nebulae salsae et mucoris normaliter operari possunt.
- Interruptores in navibus adhibiti sub vibratione normali certo modo operari possunt.
- Interruptor secundum stipulationes in manuali operationis instituendus est. Interruptoribus communibus in usu, inclinatio verticalis non maior est quam 50 gradus; interruptoribus autem in navibus, inclinatio verticalis non maior est quam 22.50 gradus.
- Interruptor in loco collocandus est ubi nullum medium explosivum et pulvis conductivus et nullum gas, quod metallum corroderet aut insulationem destrueret, adsit.
- Interruptor in compartimento tabulae commutationis installari debet et postium insuper figi debet; gradus protectionis usque ad lP40 est.
Data Technica et Facultas
| Tabula 1 fluxus nominalis |
| Currentis aestimatae structurae Inm A | Current nominalis ln A |
| MM | (400)630,800,1000,1250,1600,2000 |
| 3200 | MM, MMMD, MMCM, MMCC, MMCC |
| Quadringenta milia | 3200, 3600, 4000 |
| 6300 | 4000, 5000, 6300 |
Pro capacitate interruptionis in circuitu brevi aestimata et tolerantia brevis temporis interruptoriorum, distantia arcus "nulla" est (quia exterior pars interruptorii arcus non producitur). Tabula 2
| Currentis aestimatae structurae Inm A | | MM | 3200 | Quadringenta milia | 6300 |
Limitis aestimatae capacitatis frangendi circuitum brevem lcu(kA)O-CO | 400V | 80 | 80 | centum | CXX |
| 690V | 50 | 50 | 75 | 85 |
Capacitatem frangendi circuitum brevem aestimatam operandi nx lcu(KA)/COS∅ | 400V | 176/0.2 | 176/0.2 | 220/0.2 | 264/0.2 |
| 690V | 105/0.25 | 105/0.25 | 165/0.2 | 187/0.2 |
Brevis temporis tolerantia LCW aestimata lcs(kA)O-CO-CO | 400V | 50 | 50 | 80 | centum |
| 690V | 40 | 40 | 65 | 75 |
Brevis temporis tolerantia LCW aestimata (kA)———”+0.4s, O-CO | 400V | 50 | 50 | 65/80 (MCR) | 85/100 (MCR) |
| 690V | 40 | 40 | 50/65 (MCR) | 65/75 (MCR) |
| Nota: Filum input et output idem est ad facultatem frangendam. |
Maxima potentia destruendi est 360W pro interruptoribus, et in diversa temperatura, et cursus electricus diuturnus aestimatus mutabitur. Tabula 3
Ambientis temperatura ℃ | Current aestimatus |
| 400A | 630A | 800A | 1000A | 1250A | 1600A | MM A |
| 40 | 400A | 630A | 800A | 1000A | 1250A | 1600A | MM A |
| 50 | 400A | 630A | 800A | 1000A | 1250A | 1550A | 1900A |
| 60 | 400A | 630A | 800A | 1000A | 1250A | 1550A | MDCCCA |
Functiones et praesidium moderatoris intelligens contra nimium currentem. Configuratio et error. Tabula 4.
| Longa mora | Brevis mora | Instantaneus | Error terrestris |
| lr1 | lr2 | Error | lr3 | Error | lr4 | Error |
| (0.4-1) Intra | (0.4-15) Intra | ±10% | ln-50kA (Inm = 2000A) ln-75kA (Inm = 3200A) | ±15% | lnm = 2000 ~ 3200A (0.2-0.8) Intra (1200A, 160A) | ±10% |
| Nota: si trium graduum tutelam simul habet, configuratio non transibit. |
Mora longa super operationem temporis inversi currentis habet I₂TL, = (1.51lr1)²tL, et tempus actionis eius (1.02-2.0) Ir1, cum errore temporis ±15%. Tabula 5
| 1.05Ir1 | 1.3Ir1 | 1.5Ir1 Tempus constituendi S | 15 | 30 | 60 | CXX | 240 | 480 |
| Nulla actio | Actio <1h | Tempus constitutionis 2.0Ir S | 8.4 | 16.9 | 33.7 | 67.5 | 135 | 270 |

Praecedens: CJN-250-300M60 Modulus Solaris Monocrystallinus Deinde: CJ-219g Commutator Automaticus Commutationis Electricae Modularis 1-4p Commutator Principalis