| Typus | Indices technici |
| Exitus | Tensio continua | 5V | Duodecim voltia | 24V | 36V | 48V |
| Unda et strepitus | <50mVp-p | <120mVp-p | <150mVp-p | <240mVp-p | <240mVp-p |
| Ambitus regulationis tensionis | ±10% |
| Praecisio tensionis | ±2.0% | ±1.0% |
| Ratio adaptationis linearis | ±0.5% |
| Ratio regulationis oneris | <±1.5% | <±0.5% | <±0.5% | <±0.5% | <±0.5% |
| Inputum | Frequentia/amplitudo tensionis | 85-264VCA 47Hz-63Hz (120VCC~370VCC) |
| Efficacia (typica) | 78% | 82% | 84% | 84.00% | 84% |
| Currens impetus | 110VAC 18A, 220VAC 36A |
| Tempus incipiendi | 200ms, 50ms, 20ms; 220V AC |
| Proprietates tutelae | Protectio contra onus nimium | Emissio cursus constans +VO ad punctum pressionis demissae cadit, emissio interclusa ad reset: iterum potentia accendenda est. |
| Praesidium contra breves circuitus | +VO ad punctum pressionis demissae cadit ut emissionem claudat |
| Scientia environmentalis | Temperatura et humiditas operandi | -10°C~+50°C; 20%~90°RH |
| Temperatura et humiditas repositionis | -20°C~+85°C; 10%~95°RH |
| Securitas | Resistentia pressionis | Ingressus – egressus: 1.5KVAC ingressus-casus: 1.5KVAC egressus-casus: 0.5kvac duratio: 1 minutum |
| fluxus electricus | Ingressus-egressus 1.5KVAC <5mA |
| fluxus electricus | Ingressus-egressus 220VAC <1mA |
| Impedans insulationis | Ingressus-exitus et ingressus-cortex, ingressus-cortex: 500 VDC/100mΩ |
| Alia | Magnitudo | 159*98*38mm (L*A*A) |
| Pondus netum / pondus grossum | 436.6g/478.5g |
| Observationes | (1) Mensura undulationis et strepitus: Linea parium contortorum 12" cum condensatore 0.1µF et 47µF parallelis in terminali adhibita, mensura ad latitudinem transmissionis 20MHz perficitur. |
| (2) Efficacia probatur sub tensione ingressus 230 VCA, onere nominali et temperatura ambiente 25°C. Accuratio: errorem configurationis, rationem adaptationis linearis et rationem adaptationis oneris comprehendens. Methodus probationis rationis adaptationis linearis: probatio a tensione humili ad tensionem altam sub onere nominali. Methodus probationis rationis adaptationis oneris: ab onere nominali 0%-100%. Tempus initii metitur in statu initii frigidi, et machina commutationis frequentis celeris tempus initii augere potest. Cum altitudo supra 2000 metra est, temperatura operandi 5/1000 deminui debet. |