Series reclasorum automaticorum CJ53RAi est unitas moderandi compacta, latitudine tantum 18 mm, quae aptari potest interruptoribus automaticis miniaturizatis in foro.
| Modellum | Interruptor Circuitus | ||||||||
| MCB | RCD | RCBO | |||||||
| 1P/2P | 3P/4P | 2P | 4P | 1P | 2P | 3P | 3P+N | 4P | |
| CJ53RAi-1-AC | √ | √ | √ | √ | |||||
| CJ53RAi-2-AC | √ | √ | √ | √ | √ | ||||
| CJ53RAix-1-AC | √ | √ | √ | √ | |||||
| CJ53RAix-2-AC | √ | √ | √ | √ | √ | ||||
| CJ53RAi-1-DC | √ | √ | √ | √ | |||||
| CJ53RAi-2-DC | √ | √ | √ | √ | √ | ||||
| CJ53RAix-1-DC | √ | √ | √ | √ | |||||
| CJ53RAix-2-DC | √ | √ | √ | √ | √ | ||||
| Proprietates electricae | |||
| Norma | EN 50557 | ||
| Systema Distributionis Potentiae | TT – TN – S | ||
| Tensio Aestimata (Ue) | (V) | 230 AC (1) | |
| Minimum Tensio Aestimata (Min Ue) | (V) | 85% Ue | |
| Maxima Tensio Aestimata (Max Ue) | (V) | 110% Ue | |
| Tensio Insulationis Aestimata (Ui) | (V) | quingenti | |
| Robur Diaelectricum | (V) | 2500 AC per unum minutum | |
| Tensio tolerabilis aestimata (Uimp) | 4 | ||
| Categoria Supertensionis | III | ||
| Frequentia Aestimata | (Hz) | 50 | |
| Capacitas Frangendi Effusionis Terrestris (I△m) | (A) | I△c Interruptoris Relati | |
| Currens Brevis Circuitus Residuus Aestimatus (I△c) | (A) | Im△m Interruptoris Relati | |
| Poloni | 2 | 4 | |
| Typus MCB | 1P – 2P – 3P – 4P | ||
| Typus RCCB | AC – A – A[IR] – A[S] | ||
| Typus RCBO | |||
| Currens Aestimatus (In) | (A) | XXV – XL – LXIII – LXXX – C | |
| Currens Residuus Aestimatus (I△n) | (mA) | XXX – C – CCC – D | |
| Resistentia non operativa aestimata inter partes electricae et terra | (kΩ) | 8 (30mA) – 2,5 (100/300/500mA) | |
| Resistentia operativa aestimata inter partes vivas et terra | (kΩ) | 16 (30mA) – 5 (100/300/500mA) | |
| In iactura potentiae | (V) | Potentia amissa interruptoris circuli conexi | |
| Potentia Statica | (VA) | 1 | 1 |
| Vis claudendi automatice | (VA) | 20 | 20 |
| Proprietates Mechanicae | |||
| Latitudo Moduli DIN | 1 | 1 | |
| Intervallum Temporis Reclausurae | (s) | 10 – 60 – 300 | |
| Frequentia Operationis Maxima | (operator/h) | 30 | |
| Maxima durabilitas mechanica (numerus totalis) operationes) | Decem milia | ||
| Maximus Cyclus Reclausurae Automaticae | 60 | ||
| Numerus temporis ad restituendum numeratorem Reclausura continua operatio | (s) | 3 | |
| Pars Terminalis Interruptoris | (mm²) | Funis mollis: ≤ 1×35 – ≤ 2×16 – ≤ 1×16+2×10 | |
| Momentum stringendi aestimatum disiunctoris circuiti | (Nm) | 3 (IDP) – 2 (IDP NA) | |
| Locus institutionis | Quilibet | ||
| Gradus Protectionis Interruptoris Circuitus | IP20 () – IP40 () | ||
| Characteres Ambitus | |||
| Gradus Pollutionis | 2 | ||
| Temperatura Operis | (°C) | -25 +60 | -25 +60 |
| Temperatura Reponendi | (°C) | -40 +70 | |
| Humiditas Relativa | 55°C – RH 95% | ||
| Proprietates Contactus Auxiliaris | |||
| Auxiliaris | Ita | Ita | |
| Typus Contactus | - | Relay Electronicum | |
| Tensio Aestimata | (V) | - | 5-230 AC/DC |
| Currens Aestimatus | (A) | - | 0.6 (minimum) - 1 (maximum) |
| Frequentia | (Hz) | - | 50 |
| Utere categoria | - | AC12 | |
| Modus Operationis | - | NO\NC\ Signum positionis manubrii | |
| Nexus Funis | (mm²) | - | ≤2.5 |
| Momentum Adstringens Aestimatum | (Nm) | - | 0.4 |
| Functio Reclausurae Automaticae | |||
| Reclausura automatica cum iter electricum vitii | √ | √ | |
| Examen Culpae Terrae | |||
| Examen Effusionis Terrestris | |||
| Reclausura sistit cum vitium est | √ | √ | |
| Signum Reclausurae | |||
| Indicator Signi Culpae | √ | √ | |
| Functio Automatica / Manualis | √ | √ | |
| Contactus Auxiliaris ad Operationem Remotam | |||
| Protectio Electrica Interna | PTC | PTC | |