| Typus | Indices technici | |||||
| Exitus | Tensio continua | 5V | Duodecim voltia | 24V | 36V | 48V |
| Current aestimatus | 14A | 6A | 3.2A | 2.1A | 1.6A | |
| Potentia aestimata | 70W | 72W | 76.8W | 75.6W | 76.8W | |
| Unda et strepitus | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
| Ambitus regulationis tensionis | ±10% | |||||
| Praecisio tensionis | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| Ratio adaptationis linearis | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Ratio regulationis oneris | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Tempus surgendi stellae | 500ms, 30ms/230VAC 500ms, 30ms/115VAC (pleno onere) | |||||
| Tempus serva | 60ms/230VAC 12ms/115VA (pleno onere) | |||||
| Inputum | Frequentia/amplitudo tensionis | 85-264VAC/120-373VDC 47Hz-63Hz | ||||
| Efficacia (typica) | 87% | 89% | 90% | 91.50% | 92% | |
| Currens operans | 1.4A/115VAC 0.85A/230VAC | |||||
| Currens impetus | Initium frigidum: 65A/230VAC | |||||
| Fugae fluxus | <0.75mA 240VAC | |||||
| Proprietates tutelae | Praesidium contra onus nimium | Typus tutelae: modus ructus, remove condicionem abnormalem et automatice ad normalem redire | ||||
| Protectio contra supertensionem | Genus tutelae: claudere exitum et automatice ad statum normalem denuo incipere | |||||
| Scientia environmentalis | Temperatura et humiditas operandi | -25ºC~+70ºC; 20%~90RH | ||||
| Temperatura et humiditas repositionis | 40°C ~ +85°C; 10% ~ 95°RH | |||||
| Securitas | Resistentia pressionis | Ingressus – egressus: 4KVAC ingressus – casus: 2KVAC egressus – casus: 1.25kvac duratio: 1 minutum | ||||
| Impedans insulationis | Ingressus – egressus et ingressus – testa, egressus – testa: 500 VDC / 100 m Ω 25ºC, 70% RH | |||||
| Alia | Magnitudo | 99*97*30mm (L*A*A) | ||||
| Pondus netum / pondus grossum | 250g/272g | |||||
| Observationes | (1) Mensura undulationis et strepitus: Linea parium contortorum 12" cum condensatore 0.1µF et 47µF parallelis in terminali adhibita, mensura ad latitudinem transmissionis 20MHz perficitur. | |||||
| (2) Efficacia probatur sub tensione ingressus 230 VCA, onere nominali et temperatura ambiente 25°C. Accuratio: errorem configurationis, rationem adaptationis linearis et rationem adaptationis oneris comprehendens. Methodus probationis rationis adaptationis linearis: probatio a tensione humili ad tensionem altam sub onere nominali. Methodus probationis rationis adaptationis oneris: ab onere nominali 0%-100%. Tempus initii metitur in statu initii frigidi, et machina commutationis frequentis celeris tempus initii augere potest. Cum altitudo supra 2000 metra est, temperatura operandi 5/1000 deminui debet. | ||||||
Praecipuum commodum fontis potentiae commutantis est maior efficacia (usque ad ~98–99%) et conexa minor caloris generatio quam regulatores lineares, quia transistor commutans parvam potentiae dissipat cum fungitur ut commutator.