• 1920x300 nybjtp

Interruptor automaticus protectionis motoris MPCB 80A altae efficacitatis, initiator motoris, adaptabilis.

Descriptio Brevis:

  • Interruptor automaticus protectionis motoris seriei GV2 (etiam appellatus ut Protector Motoris vel initiator Motoris, posthac "interruptor automaticus" appellatus) aptus est tensioni AC usque ad 690V, maximae intensitatis usque ad 80A, et functiones interruptoris automatici isolationis, interruptoris automatici, et relais thermalis habet. Protectionem isolationis, protectionem contra onerationem excessivam, compensationem temperaturae, protectionem contra interruptionem phasis, et protectionem contra circuitum brevem habet. Ambitus applicationis: motor asynchronus triphasicus in cavea muris, initium directum et imperium, protectio lineae distributionis, et conversio oneris rara.
  • Interruptor automaticus GV2 normis GB/T14048.2, GB/T14048.4, IEC60947-2, 60947-4-1 obtemperat.

Detalia Producti

Etiquettae Productarum

Conditiones normales operis et institutionis

  • Altitudo loci installationis plerumque non plus quam duo milia metra est.
  • Limes inferior temperaturae aeris ambientis plerumque non est inferior quam -5°C, et limes superior plerumque non est superior quam +40°C.
  • Humiditas relativa aeris non plus quam 50% est cum temperatura +40°C est, et minima temperatura menstrua mensis pluviosissimi 25°C est, et maxima humiditas relativa media menstrua non plus quam 90%.
  • Gradus pollutionis ambitus circumstans est 3.
  • Categoriae installationis initialis sunt lIl.
  • Inclinatio superficiei montandae et plani verticalis non plus quam ±5° est.
  • Systema operis aestimatum: systema operis continui, systema operis intermittentis.

Parametri technici principales

  • Tensio insulationis aestimata Ui(V): 690.
  • Tensio impulsiva nominalis tolerabilis Uimp(kV): 8.
  • Tensio operativa aestimata Ue(V): 230/240, 400/415, 440, 500, 690.
  • Frequentia nominalis (Hz): 50,60.
  • Currentis aestimata structurae Inm(A): 32A, 80A.
  • Cursus nominalis In(A): vide Tabulam 1.
  • Adaptatio currentis conformationis partis calidae·Pro ambitu: limes nominalis et capacitas nominalis interrumpendi in brevi circuitu operativo, vide Tabulam 1.
  • Potentia nominalis normalis motoris triphasici ab interruptore automatico gubernati in tabula 2 ostenditur.

 

Tabula 1

Modellum Claustrum aestimatum
currentis In (A)
Currens adaptationis
spatium adaptationis
(A)
Limite nominale capacitatis frangendi circuitum brevem Icu
Facultas interruptionis circuitus brevis operationis nominalis Ics kA
Arcus
distantia
(mm)
400/415V 690V
Unitatem curarum intensivarum (UCI) Ics Unitatem curarum intensivarum (UCI) Ics
GV2-ME32(X/P) 0.16 0.1~0.16 centum centum centum centum 40
GV2-ME32(X/P) 0.25 0.16~0.25 centum centum centum centum 40
GV2-ME32(X/P) 0.4 0.25~0.4 centum centum centum centum 40
GV2-ME32(X/P) 0.63 0.4~0.63 centum centum centum centum 40
GV2-ME32(X/P) 1 0.63~1 centum centum centum centum 40
GV2-ME32(X/P) 1.6 1~1.6 centum centum centum centum 40
GV2-ME32(X/P) 2.5 1.6~2.5 centum centum 3 2.25 40
GV2-ME32(X/P) 4 2.5~4 centum centum 3 2.25 40
GV2-ME32(X/P) 6.3 4~6.3 centum centum 3 2.25 40
GV2-ME32(X/P) 10 VI~X centum centum 3 2.25 40
GV2-ME32(X/P) 14 9~14 15 7.5 3 2.25 40
GV2-ME32(X/P) 18 XIII~XVIII 15 7.5 3 2.25 40
GV2-ME32(X/P) 23 XVII~XXIII 15 6 3 2.25 40
GV2-ME32(X/P) 25 XX~XXV 15 6 3 2.25 40
GV2-ME32(X/P) 32 XXIV~XXXII 10 6 3 2.25 40
GV3-ME80 25 XVI~XXV 15 7.5 4 2 50
GV3-ME80 40 XXV~XL 15 7.5 4 2 50
GV3-ME80 63 40~63 15 7.5 4 2 50
GV3-ME80 80 56~80 15 7.5 4 2 50

 

Tabula II

Modellum Current nominalis fibulae In (A) Currens adaptationis
spatium adaptationis
(A)
Potentia nominalis normalis motoris triphasici (kW)
AC-3,50Hz/60Hz
230/240V 400V 415V 440V 500V 690V
GV2-ME32(X/P) 0.16 0.1~0.16 - - - - - -
GV2-ME32(X/P) 0.25 0.16~0.25 - - - - - -
GV2-ME32(X/P) 0.4 0.25~0.4 - - - - - -
GV2-ME32(X/P) 0.63 0.4~0.63 - - - - - 0.37
GV2-ME32(X/P) 1 0.63~1 - - - 0.37 0.37 0.55
GV2-ME32(X/P) 1.6 1~1.6 - 0.37 - 0.55 0.75 1.1
GV2-ME32(X/P) 2.5 1.6~2.5 0.37 0.75 0.75 1.1 1.1 1.5
GV2-ME32(X/P) 4 2.5~4 0.75 1.5 1.5 1.5 2.2 3
GV2-ME32(X/P) 6.3 4~6.3 1.1 2.2 2.2 3 3.7 4
GV2-ME32(X/P) 10 VI~X 2.2 4 4 4 5.5 7.5
GV2-ME32(X/P) 14 9~14 3 5.5 5.5 7.5 7.5 9
GV2-ME32(X/P) 18 XIII~XVIII 4 7.5 9 9 9 11
GV2-ME32(X/P) 23 XVII~XXIII 5.5 11 11 11 11 15
GV2-ME32(X/P) 25 XX~XXV 5.5 11 11 11 15 18.5
GV2-ME32(X/P) 32 XXIV~XXXII 7.5 15 15 15 18.5 25
GV3-ME80 25 XVI~XXV - 11 11 - - 18.5
GV3-ME80 40 XXV~XL - 18.5 18.5 - - 37
GV3-ME80 63 40~63 - 30 30 - - 55
GV3-ME80 80 56~80 - 37 37 - - 63

  • Classis protectionis clausurae est lP20.
  • Functio operativa interruptorii automatici in Tabula III monstratur.

 

Tabula III

Modellum Rack aestimatum
praesens Inm A
Operatio horaria
cycli
Numerus cycli operationis
Vita electrica Vita Mechanica
GV2-ME32(X/P) 32 CXX Decem milia Decem milia
GV3-ME80 80 CXX 1500 8500

GV2 GV3 Interruptor circuitus protectionis motoris

 

Quomodo exemplar eligere?

GV2 GV3 Interruptor circuitus protectionis motoris 01


  • Praecedens:
  • Deinde:

  • Nuntium tuum hic scribe et nobis mitte.