EXEMPLUM | HDR-100-12 | HDR-100-15 | HDR-100-24 | HDR-100-48 |
DC Voltage | 12v | 15V | 24v | 48v |
Ratum Current | 7.5A | 6.5A | 4.2A | 2.1A |
Current range | 0~7.5A | 0~6.5A | 0~4.2A | 0~2.1A |
Rated potestas | 90w | 97.5w | 100.8w | 100.8W |
Ripple & noise(max.) | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p |
CONTENTIO ADJ.range | 12~13.8V | 13.5~ 18V | 21.6~29V | 43.2~55.2V |
tolerantia intentione | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
Recta ordinatio | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Ordinatio onus | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Setup, Surge, Tempus | 500ms, 60ms/230VAC 500ms, 60ms/115VAC (onus plenum) | |||
Sustenta tempus | 30ms/230VAC 12ms/115VAC(plenum onus) | |||
Voltage range | 85~ 264VAC(277VACusable) 120~ 370VDC(390VDCusable) | |||
Voltage range | 50~60Hz | |||
Efficientia | 88% | 89% | 90% | 90% |
AC current | 3A/115VAC 1.6A/230VAC | |||
Incurrere current | Initium frigidum: 35A/115VAC 70A/230VAC | |||
Per onus | CV ~ CL% rated output potentia | |||
Modus munitus: modus current constans, automatice restitui potest post condicionem abnormalem remotam | ||||
Per voltage | 14.2~16.2V | 18.8~22.5V | 30~36V | 56.5~64.8V |
Tutela modus;Claudere output et sileo ut restituat | ||||
opus TEMP | -30~+70ºC | |||
opus humiditas | 20~90% RH, non-condensing | |||
Repono TEMP humiditas | -40~+85ºC,10-95%RH,non-condensing | |||
TEMP.coefficient | ±0.03%ºC(0~50ºC) | |||
Vibratio | 10~ 500Hz,2G 10min./1cycle,60min.a singulis X, Y, Z inauguratis securibus IEC60068-2-6 conformis. | |||
Altitudo operating | 2000m | |||
Classis super voltage | Secundum EN61558 EN50178 EN60664-1, EN62477-1; | |||
sustinere voltage | I/PO/P4KVAC | |||
Insolation resistentia | I/PO/P:100M Ohms 500VDc / 25ºC/70% RH | |||
MTBF | ≥856.5K hrs.MIL-HDBK-217F(25ºC) | |||
Dimension | 70*90*54.5mm (W*H*D) | |||
stipare | 0.27Kg;48pcs/14Kg/0.6CUFT |