CRS-100,120 series est 100,120W unius coetus output clausus copiae cum 30mm humili consilio profile, 85-264VAC plena range AC initus utens, tota series 5V,12V,15V,24V,36V et 48V output praebet.
Type | Technical Indicatores | |||||
Output | DC voltage | 5V | 12V | 24V | 36V | 48V |
Ratum current | 18A | 8.5A | 4.5A | 2.8A | 2.3A | |
Rated potestas | 90W | 102W | 108W | 100.8W | 110.4W | |
Ripple et sonitus | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Ordinatio intentione range | ±10% | |||||
intentione subtilitatis | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Linearibus temperatio rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Ordinatio rate onus | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Star in tempore | 500ms、300ms/230VAC 500ms、30ms/115VAC(plenum onus) | |||||
Serva tempus | 55ms/230VAC 10ms/115VA (onus plenum) | |||||
Input | Voltage range / frequentia | 85-264VAC/120-373VDC 47Hz-63Hz | ||||
Efficens (typcial) | 86% | 88% | 90% | 90.50% | 91% | |
opus current | 1.9A/115VAC 1.2A/230VAC | |||||
Inpulsa current | Initium frigidum: 50A/230VAC | |||||
Lacus current | <1mA 240VAC | |||||
Praesidium characteres | ONERO praesidium | Praesidium genus: burp modum, condicionem abnormalem remove et automatice ad normalem redire | ||||
Overvoltage praesidium | Praesidium genus: proxima output et sileo automatice ad normalem | |||||
Environmental scientia | Operatio caliditas et humiditas | -30℃~+70℃;20%~90RH | ||||
Repono caliditas et humiditas | -40℃~+85℃;10%~95RH | |||||
Securitas | Pressura resistentia | Input - output: 4KVAC initus-casu: 2KVAC output -case: 1.25kvac duratione: I momento | ||||
lnsulation impedimentum | Input - output and input - putamen, output - putamen: 500 VDC/100 m Ω 25℃,70% RH | |||||
Other | Magnitudo | 129*97*30mm(L*W*H) | ||||
Net pondus / crassa pondus | 340g/365g | |||||
Dicta | (1) Mensuratio laniatus et strepitus: Utens 12″ retorta linea cum capacitore 0.1uF et 47uF in parallelo in termino, mensuratio fit ad 20MHz latitudinem. (2) Eificientia probatur in intentione initus 230VAC, aestimata onere et 25℃ ambiente temperatura. Accuracy: inter occasum erroris, ratae commensurationis linearis et oneris accommodationis rate. Test methodus temperatio- nis linearis: festing ab humili intentione ad altam intentionem. aestimavit onus temperatio rate test modum: ab 0%-100% aestimavit load. Tempus satus-sursum mensuratur in statu frigido initio, et ieiunium frequentes apparatus switch satus sursum time potest crescere. Cum altitudo supra 2o000 metrorum est, temperatura operativa ab 5/1000 demitti debet. |