In Sinis factum CJL16-40 AC Typus 1P+N Interruptor Circuitus Residualis cum Protectione Supercurrentis RCBO

Descriptio Brevis:

  • Praebet tutelam contra defectum terrae/currentem emissum, circuitum brevem, onerationem electricam, et functionem isolationis.
  • Praebet praesidium complementarium contra contactum directum corporis humani.
  • Efficaciter apparatum electricum contra defectum insulationis protegit.
  • Praebet tutelam completam systematibus distributionis domesticis et commercialibus.

Detalia Producti

Etiquettae Productarum

Data Technica

Normae IEC/EN61009-1
Typus Typus electromagneticus
Proprietates currentis residuae AC A
Polus No. 1P+N
Curva discessionis B, C, D
Capacitas circuitus brevis aestimata 10kA
Current nominalis (A) 1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A
Tensio aestimata 240V AC
Frequentia aestimata 50/60Hz
Currens residuum operandi aestimatus (mA) 0.03, 0.1, 0.3
Duratio itineris instantanea ≤ 0.1s
Tolerantia electromechanica Quadringenti milia cyclorum
Terminalis connexionis terminalis columnae cum fibula
Capacitas connexionis: Conductor rigidus 16mm²
Altitudo connexionis terminalis 21.5mm
Installatio In ferreo DIN symmetrico 35mm
Affixatio tabularum
Schema Filorum

Proprietates Protectionis Currentis Oneris Excessivi

Modus probationis Typus Currens Probationis Status Initialis Tempus Limitis Prolapsus vel Non-Prolapsus Resultatum Expectatum Nota
a B, C, D 1.13 pollices frigidus t≥1h Nulla lapsus
b 1.45 pollices post experimentum a hora <1 lapsus Current in 5s in incremento stabilitatis
c 2.55in frigidus 1s < t < 60s lapsus
d B Tres Intra frigidus t≥0.1s Nulla lapsus Interruptorem auxiliarem accende ut
claude cursum
C Quinque Intra
D Decem Intra
e B Quinque Intra frigidus t <0.1s lapsus Interruptorem auxiliarem accende ut
claude cursum
C Decem Intra
D XX Intra
Terminus "status frigidus" ad id refertur quod nullum onus portatur ante probationem ad temperaturam referentialem constitutam.

 

Tempus Interruptionis Actionis Currentis Residuae

Typus Intra/A I△n/A Currens Residuus (I△) Tempori Interruptionis Sequenti (S) Respondet
Typus AC ullus valor ullus valor In DuoIn Quinque Intra 5A, 10A, 20A, 50A, 100A, 200A, 500A
Typus ullus valor >0.01 1.4 pollices 2.8 pollices Septem Intra
0.3 0.15 0.04 0.04 Tempus Pausae Maximum
Interruptor differenzialis (RCBO) generis generalis, cuius IΔn fluxus electricus 0.03mA vel minus est, 0.25A loco 5IΔn uti potest.

 