• 1920x300 nybjtp

CJ-C40m 1.5ka 40ka Instrumentum Protectionis Impetus Solaris DC SPD pro Systemate Solari PV

Descriptio Brevis:

Constructio et Proprietates

  • Locus Usus: Tabulae Sub-Distributionis
  • Modus Protectionis: LN, N-PE
  • Aestimationes Impetus: In = 20kA (8/20μs)
  • Categoria IEC/EN/UL: Classis I+II / Typus 1+2
  • Elementa Protectoria: MOV et GDT Altae Energiae
  • Involucrum: Designatio Inseribilis
  • Conformitas: IEC 61643-11:2011 / EN 61643-11:2012

 

Instrumentum tutelae contra impetus electricos, paralleliter connexum, impedantiam magnam habet. Aliis verbis, summa impedantiae seriei aequalis est impedantiae unius instrumenti tutelae. Cum tensio electrica maxima transitoria intra systema apparet, impedantia instrumenti decrescit, ita fluxus electricus per instrumentum tutelae agitur, apparatum sensibile praetereundo. Hoc fit ad instrumentum protegendum contra impetus electricos et perturbationes, ut aculeos tensionis et impetus electrici, variationes frequentiae, et tensiones maximas ab operationibus commutationis vel fulminibus causatas. Cum usor fasciam tensionis electricae vel instrumentum tutelae in lineam electricam a societate electrica quae condensatores lenientes includit installat, suppressores impetus electrici non necessarii sunt, quia hi condensatores iam contra mutationes repentinas in gradu tensionis protegunt.


Detalia Producti

Etiquettae Productarum

Data Technica

IEC Electrica CL 275 CCCXX 385 440
Tensio AC Nominalis (50/60Hz) 120V 230V 230V 230V 400V
Maxima Tensio Operativa Continua (AC) (LN) Uc 150V 275V 320V 385V 440V
(N-PE) Uc 255V
Currens Emissionis Nominalis (8/20μs) (LN)/(N-PE) In 20kA/20kA
Maxima Currens Exonerationis (8/20μs) (LN)/(N-PE) Imax 40kA/40kA
Impulsus Fluxus Exonerationis (10/350μs) (LN)/(N-PE) Imp 7kA/25kA
Gradus Protectionis Tensionis (LN)/(N-PE) Up 1.0kV/1.5kV 1.5kV/1.5kV 1.6kV/1.5kV 1.8kV/1.5kV 2.0kV/1.5kV
Sequere Aestimationem Interruptionis Currentis (N-PE) Si Centum Arma
Tempus Responsionis (LN)/(N-PE) tA <25ns/<100ns
Fusus Subsidiarius (max) 63A gL/gG
Cursus Brevis Circuitus Aestimatus (AC) (LN) ISCCR 25kA
TOV Resistere 5s (LN) UT CLXXXV 335V 335V 335V 580V
TOV 120 min. (LN) UT 230V 440V 440V 440V 765V
modus Resistere Defectus Tutus Defectus Tutus Defectus Tutus Defectus Tutus
TOV resistit 200ms (N-PE) UT 1200V
Ambitus Temperaturae Operativae Ta -40°F ad +158°F [-40°C ad +70°C]
Humiditas Operativa Permissa RH 5%…95%
Pressio atmosphaerica et altitudo 80k Pa..106k Pa/-500m..2000m
Torques Cochleae Terminalis (LN) Mmax
(PE) Mmax 39.9 lbf-in [4.5 Nm]
Sectio Transversa Conductoris (LN) 5 AWG (Solidum, Filum) / 7 AWG (Flexibile)
16 mm² (Solidum, Filum Conexum) / 10 mm² (Flexibile)
(PE) 2 AWG (Solidum, Filum) / 4 AWG (Flexibile)
35 mm² (Solidum, Filum Conexum) / 25 mm² (Flexibile)
Montatio Ferrivia DIN 35 mm, EN 60715
Gradus Protectionis IP 20 (intus)
Materia Domus Thermoplasticum: Gradus Extinctionis UL 94 V-0
Protectio Thermalis Ita
Status Operandi / Indicatio Culpae Viridis bene / Ruber vitium
Contactus Remoti (RC) Facultativum
Capacitas Commutationis RC AC:250V/0.5A;DC:250V/0.1A;125V/0.2A;75V/0.5A
Sectio Transversa Conductoris RC (max) 16 AWG (Solidum) / 1.5 mm² (Solidum)
Torques Cochleae Terminalis RC 2.2 lbf·in [0.25 Nm]

Instrumentum Protectionis Contra Impetus Fluctuum (2)

 

 


  • Praecedens:
  • Deinde: