Interruptor automaticus in capsa formata seriei CJMM1 (deinceps interruptor automaticus appellatus) adhibetur ad circuitum retium distributionis potentiae AC 50/60HZ cum tensione insulationis nominali 800V, tensione operationis nominali 690V, et currente operationis nominali ab 10A ad 630A. Ad distribuendam potentiam et prohibendum damnum circuiti et apparati potentiae ob onerationem excessivam, circuitum brevem, tensionem debilem, et alia vitia, adhibetur. Etiam ad infrequentem initium motoris, necnon ad protectionem contra onerationem excessivam, circuitum brevem, et tensionem debilem, adhibetur. Hic interruptor automaticus commoda habet voluminis parvi, capacitatis altae interceptionis, arcus brevis (vel nuarcing) etc.; accessionibus ut contactus alarmis, emissor shunt, contactus auxiliaris, etc., instrueri potest; productum ideale est usori. Interruptor automaticus currentis residualis vel verticaliter (installatio verticalis) vel horizontaliter (installatio horizontalis) installari potest. Productum secundum normas IEC60947-2 et Gb140482 est.


Detalia Producti

Etiquettae Productarum

Exemplar Producti

CJ:Codex societatis
M: Interruptor circuitus in capsa formata
1: Numerus Designationis
□: Currens nominalis structurae
□: Codex proprietatis capacitatis frangendae / S significat genus normale (S omitti potest) H significat genus altiorem

Nota: Quattuor genera poli neutri (poli N) pro producto quattuor phasium sunt. Polus neutrus typi A elemento detonante supercurrenti non instructus est, semper accensus est, et non accenditur vel extinguitur una cum tribus aliis polis.
Polus neutrus typi B elemento disjonctorio a nimia currentia non instructus est, et una cum tribus aliis polobus accenditur vel extinguit (polus neutrus accenditur antequam extinguit). Polus neutrus typi C elemento disjonctorio a nimia currentia instructus est, et una cum tribus aliis polobus accenditur vel extinguit (polus neutrus accenditur antequam extinguit). Polus neutrus typi D elemento disjonctorio a nimia currentia instructus est; semper accenditur nec una cum tribus aliis polobus accenditur vel extinguit.

Tabula 1

Nomen accessorii Emissio electronica Emissio composita
Contactus auxiliaris, liberatio sub tensione, contactus alarmis 287 378
Duo contactus auxiliares, contactus alarmis 268 368
Emissio shunt, contactus alarmis, contactus auxiliaris 238 348
Sub liberatione tensionis, contactus alarmis 248 338
Contactus auxiliaris contactus alarmis 228 328
Contactus alarmis emissionis shunt 218 318
Contactus auxiliaris liberationis tensionis minimae 270 370
Duo contactus auxiliares 260 360
Emissio shunt liberationis tensionis minimae 250 350
Contactus auxiliaris liberationis shunt 240 340
Liberatio tensionis inferioris 230 330
Contactus auxiliaris 220 CCCXX
Emissio derivationis 210 CCCX
Contactus alarmis 208 308
Nullum accessorium ducenti trecenti

Classificatio

  • Secundum capacitatem frangendi: a genus commune (genus S) b genus capacitatis frangendi altioris (genus H)
  • Per modum connexionis: a nexus tabulae anterioris, b nexus tabulae posterioris, c genus insertionis
  • Modus operationis: a operatio manubrii directa, b operatio manubrii rotatoria, c operatio electrica
  • Secundum numerum polorum: 1P, 2P, 3P, 4P
  • Per accessorium: contactum alarmis, contactum auxiliarem, emissio shunt, emissio sub tensione

Conditio Servitii Normalis

  • Altitudo loci installationis non excedere debet 2000m.
  • Temperatura aeris ambientis
  • Temperatura aeris ambientis non excedere debet +40℃
  • Valor medius +35℃ intra 24 horas non excedere debet.
  • Temperatura aeris ambientis non minor quam -5℃ esse debet.
  • Status atmosphaerae:
  • Humiditas relativa atmosphaerae hic ad maximam temperaturam +40°C 50% non excedere debet, et maior esse potest ad temperaturam inferiorem; cum media infima temperatura in mense pluvioso 25°C non excedit, 90% esse potest; condensatio in superficie producti propter mutationem temperaturae in rationem ducenda est.
  • Gradus pollutionis est classis 3

Parametrus Technicus Praecipuus

1 Valor nominalis interruptoriorum automatariorum
Modellum Imax (A) Specificationes (A) Tensio Operationis Aestimata (V) Tensio Insulationis Aestimata (V) Icu (kA) Ics (kA) Numerus Polonorum (P) Distantia Arcus (mm)
CJMM1-63S 63 6, 10, 16, 20
25, 32, 40,
50,63
quadringenti quingenti Decem* 5* 3 ≤50
CJMM1-63H 63 quadringenti quingenti XV* Decem* 3,4
CJMM1-100S centum XVI, XX, XXV, XXXII
40, 50, 63,
LXXX milia centum
DCXC DCCC XXXV/X XXII/V 3 ≤50
CJMM1-100H centum quadringenti DCCC 50 35 2, 3, 4
CJMM1-225S 225 100, 125,
CLX, CLXXX,
200,225
DCXC DCCC XXXV/X XXV/V 3 ≤50
CJMM1-225H 225 quadringenti DCCC 50 35 2, 3, 4
CJMM1-400S quadringenti 225,250,
CCCXV,CCCL,
quadringenti
DCXC DCCC 50/15 XXXV/VIII 3,4 ≤100
CJMM1-400H quadringenti quadringenti DCCC 65 35 3
CJMM1-630S DCXXX quadringenta milia quingenta
DCXXX
DCXC DCCC 50/15 XXXV/VIII 3,4 ≤100
CJMM1-630H DCXXX quadringenti DCCC 65 45 3
Nota: Cum parametri probationis pro 400V, 6A sine liberatione calefactionis
2 Characteristica operationis interruptionis temporis inversi cum uterque polus liberationis supercurrentis ad distributionem potentiae simul accenditur.
Res probationis Current (I/In) Area temporis probationis Status initialis
Current non-disruptivus 1.05in 2h(n>63A), 1h(n<63A) Status frigidus
Currentis disruptionis 1.3in 2h(n>63A), 1h(n<63A) Perge statim
post probationem primam
3 Characteristica operationis interruptionis temporis inversi cum uterque polus super-
emissio curenti pro protectione motoris simul accenditur.
Constitutio temporis conventionalis praesentis Status initialis Nota
1.0in >2h Status Frigidus
1.2 pollices ≤2h Statim post probationem primam processit.
1.5 pollices ≤4 min Status Frigidus 10≤In≤225
≤8 min Status Frigidus 225≤In≤630
7.2in 4s ≤ T ≤ 10s Status Frigidus 10≤In≤225
6s ≤ T ≤ 20s Status Frigidus 225≤In≤630
4 Proprietas operationis instantaneae interruptorii automatici ad distributionem potentiae constituetur ut 10in+20%, et interruptorii automatici ad protectionem motoris constituetur ut 12in±20%.

Magnitudo Installationis Adumbratae

CJMM1-63, 100, 225, Magnitudines Adumbrationis et Installationis (Nexus Tabulae Anterioris)

Magnitudines (mm) Codex Exemplaris
CJMM1-63S CJMM1-63H CJMM1-63S CJMM1-100S CJMM1-100H CJMM1-225S CJMM1-225
Magnitudines Adumbrationum C 85.0 85.0 88.0 88.0 102.0 102.0
E 50.0 50.0 51.0 51.0 60.0 52.0
F 23.0 23.0 23.0 22.5 25.0 23.5
G 14.0 14.0 17.5 17.5 17.0 17.0
G1 6.5 6.5 6.5 6.5 11.5 11.5
H 73.0 81.0 68.0 86.0 88.0 103.0
H1 90.0 98.5 86.0 104.0 110.0 127.0
H2 18.5 27.0 24.0 24.0 24.0 24.0
H3 4.0 4.5 4.0 4.0 4.0 4.0
H4 7.0 7.0 7.0 7.0 5.0 5.0
L 135.0 135.0 150.0 150.0 165.0 165.0
L1 170.0 173.0 225.0 225.0 360.0 360.0
L2 117.0 117.0 136.0 136.0 144.0 144.0
W 78.0 78.0 91.0 91.0 106.0 106.0
W1 25.0 25.0 30.0 30.0 35.0 35.0
W2 - 100.0 - 120.0 - 142.0
W3 - - 65.0 65.0 75.0 75.0
Magnitudines Installationis A 25.0 25.0 30.0 30.0 35.0 35.0
B 117.0 117.0 128.0 128.0 125.0 125.0
od 3.5 3.5 4.5 4.5 5.5 5.5

CJMM1-400,630,800, Magnitudines Adumbrationis et Installationis (Nexus Tabulae Anterioris)

Magnitudines (mm) Codex Exemplaris
CJMM1-400S CJMM1-630S
Magnitudines Adumbrationum C 127 134
C1 CLXXIII CLXXXIV
E 89 89
F 65 65
G 26 29
G1 13.5 14
H 107 111
H1 CL CLXII
H2 39 44
H3 6 6.5
H4 5 7.5
H5 4.5 4.5
L 257 271
L1 465 475
L2 225 234
W CL CLXXXIII
W1 48 58
W2 198 240
A 44 58
Magnitudines Installationis A1 48 58
B 194 ducenti
Od 8 7

Schema Connexionis Excisae Tabulae Posterioris et Insertionis

Magnitudines (mm) Codex Exemplaris
CJMM1-63S
CJMM1-63H
CJMM1-100S
CJMM1-100H
CJMM1-225S
CJMM1-225H
CJMM1-400S CJMM1-400H CJMM1-630S
CJMM1-630H
Magnitudines Typi Coniunctionis Tabulae Posterioris A 25 30 35 44 44 58
od 3.5 4.5*6
foramen profundum
3.3 7 7 7
od1 - - - 12.5 12.5 16.5
od2 6 8 8 8.5 9 8.5
oD 8 24 26 31 33 37
oD1 8 16 20 33 37 37
H6 44 68 66 60 65 65
H7 66 108 110 CXX CXX 125
H8 28 51 51 61 60 60
H9 38 65.5 72 - 83.5 93
H10 44 78 91 99 106.5 112
H11 8.5 17.5 17.5 22 21 21
L2 117 136 144 225 225 234
L3 117 108 124 194 194 ducenti
L4 97 95 9 CLXV CLXIII CLXV
L5 138 CLXXX 190 285 285 302
L6 80 95 110 145 CLV CLXXXV
M M6 M8 M10 - - -
K 50.2 60 70 60 60 centum
J 60.7 62 54 129 129 123
M1 M5 M8 M8 M10 M10 M12
W1 25 35 35 44 44 58

Quid est MCCB?

Interruptores automatici in capsa formata sunt instrumenta tutelae electricae quae designantur ad circuitum electricum a nimio currente protegendum. Hic nimius currentis potest oriri ex nimia oneratione vel circuitu brevi. Interruptores automatici in capsa formata adhiberi possunt in ampla varietate tensionum et frequentiarum cum definito limite inferiore et superiore optionum discessionis adaptabilium. Praeter mechanismos discessionis, interruptores automatici etiam adhiberi possunt ut interruptores disiunctionis manualis in casu necessitatis vel operationum sustentationis. Interruptores automatici normati et probantur pro nimio currente, impulsu tensionis, et protectione contra errores ut operatio tuta in omnibus ambitus et applicationibus praestetur. Efficaciter operantur ut interruptores repositionis pro circuitu electrico ad vim disiungendam et damnum minuendum a nimio currente, errore terrae, circuitibus brevibus, vel cum current limitem currentis excedit.

 

Momentum Capsae FormaeInterruptor Circuitusin Salute Electrica Curanda

In mundo hodierno, electricitas pars magna vitae nostrae quotidianae est. A domibus nostris potentia electrica praebendis ad machinas industriales operandas, salus et firmitas systematum electricorum curanda est maximi momenti. Interruptor circuitus in capsa formata (MCCB) pars clavis est quae partes magnas agit. In hoc diario, momentum MCCB in salute electrica curanda explorabimus.

MCCB est instrumentum tutelae electricae destinatum ad circuitus et apparatum a oneribus nimiis et circuitibus brevibus protegendos. Vulgo in applicationibus domesticis, commercialibus et industrialibus adhibentur ad damnum systematibus electricis prohibendum et, quod magis interest, periculum incendiorum electricorum minuendum.

Una ex praecipuis functionibus MCCB est interrumpere fluxum currentis si nimium onus afferatur aut circuitus brevis accidat. Hoc magni momenti est ad prohibendum ne fila et partes nimis calefiant, quod ad incendia et damna catastrophica ducere potest. Circuitus interrumpendo et vim electricam intercludendo, MCCB adiuvant ad vitanda pericula potentialia et ad protegendos homines et res.

Praeterea, MCCB commoditatem et flexibilitatem systematibus electricis praebet. Post interruptionem facile restitui possunt, quo facto potentia celeriter restituatur sine necessitate ullarum partium substituendarum. Hoc non solum tempus et laborem servat, sed etiam tempus inoperabile et perturbationem operationum quotidianarum minuit.

Praeter munus pericula electrica prohibendi, interruptores automatarii in capsa formata efficientiam et firmitatem systematum electricorum augent. Contra onera excessiva et circuitus breves protegendo, integritatem apparatuum electricorum conservant et vitam eorum utilem extendunt. Hoc vicissim necessitatem reparationum et substitutionum sumptuosarum minuit, tempus et pecuniam in longo spatio conservans.

Notandum est non omnes MCCBs eosdem esse. Cum MCCB pro certa applicatione eligis, magni momenti est considerare factores ut aestimatio currentiae, facultas frangendi et tensio operativa. Hae specificationes diligenter congruere debent cum requisitis systematis electrici ut debita protectio et efficacia praestentur.

Praeterea, cura et probatio regularis MCCB necessariae sunt ad eius efficaciam continuam confirmandam. Inspectiones et probationes regulares adiuvare possunt ad inveniendas quaslibet difficultates potentiales vel detritionem, ut reparationes vel substitutiones, prout opus est, fieri possint.

Summa summarum, interruptores automatarii formati partes vitales agunt in securitate et fidelitate electrica curanda. Contra onera excessiva et circuitus breves protegendo, pericula electrica vitare et periculum ignis minuere adiuvant. Praeterea, efficientiam et diuturnitatem systematum electricorum augere adiuvant, ita ut pars indispensabilis in installationibus electricis modernis fiat. In interruptores automatarios qualitate praeditos investire et recte conservari curare essentiale est ad homines et res a periculis errorum electricorum protegendos.


  • Praecedens:
  • Deinde:

  • Nuntium tuum hic scribe et nobis mitte.